Datalogger
WSD12-4D - Potentiometric sensor input - Temperature
4-channel Wireless Smart Data Logger - 3 inputs for potentiometric transducer (selectable stroke) and air temperature (ambient/contact) or additional input for potentiometric transducer. Lithium ‘C’ battery for up to 10 years of autonomy with hourly sampling - IP65.
€ 677,60
VAT and shipping excluded
Contact us
- Technical data
- Downloads
- Related products
- Case Studies
| Power supply | 8.5Ah - 3.6V type “C” lithium internal battery (BAT2) |
| Battery life (*) | Up to 10 years (samples every 60 minutes and radio signal quality at least sufficient) |
| Measures acquired (4 input channels) | · Linear deformation · Proportional measure· Temperature |
| Sampling interval (*) | Selectable from one minute to 24 hours (60 minutes default) |
| Datalogger capacity | 64,000 samples (for each channel) |
| Working temperature | · Operative: -30°C ÷ +60°C · Warehousing: -40°C ÷ +70°C |
| Radio frequency | ISM 868MHz |
| Radio coverage | Up to 6Km in line of sight (can be extended using WR12 battery powered repeaters) |
| Sealing | IP65 |
| Dimensions | 90x160x50mm |
| Weight | 450g |
| Case material | ABS |
| Mounting | Fix on 4 points |
| Connections | Wireless, USB |
| Cable external diameter | 4.7mm maximum |
| Copper wire section | 0.05 ÷ 2.5mm² / ÷ 14 AWG |
| Temperature - Transducer type | NTC10KΩ |
| Temperature - Measure range | -30°C÷+60°C |
| Temperature - Measure accuracy | · ±0.5°C Range -30°C÷0°C · ±0.2°C Range 0°C÷+60°C |
| Temperature - Measure resolution | 0.01°C |
| Proportional measure - Transducer type | Potentiometer |
| Proportional measure - Measure range | 0÷100% |
| Proportional measure - Measure resolution | 0.01% |
| Linear deformation - Transducer type | Potentiometer |
| Linear deformation - Measure range | Configurable using WineCapManager - From 1mm up to 10,000mm |
| Linear deformation - Measure accuracy | 0.1% analog input - Refer to potentiometer’s technical sheet |
| Linear deformation - Measure resolution | 14bit |
* battery life may be influenced by fieldwork conditions, sampling/measuring interval and system configuration.
** radio coverage can be extended using up to 32 WR12 repeaters (maximum 16 for each path) between the device and the gateway.
** refer to selected transducer’s documentation. Setup DIP switches in proper way.
- PZ12-A-050 - Rectilinear displacement transducer
- NTC10KSUP - 0.1°C accuracy in 0°C÷+60°C range NTC10K
- PY2-F-025 - Rectilinear displacement transducer with ball tip
- PY2-F-050 - Rectilinear displacement transducer with ball tip
- PY2-F-100 - Rectilinear displacement transducer with ball tip
- PZ12-A-010 - Rectilinear displacement transducer with cylindrical case
- PZ12-A-025 - Rectilinear displacement transducer with cylindrical case
- PZ12-A-100 - Rectilinear displacement transducer with cylindrical case
- PZ12-A-200 - Rectilinear displacement transducer with cylindrical case
- PZ67A-50 - Selfaligning Rectilinear displacement with IP67 sealing
- PZ67A-100 - Selfaligning Rectilinear displacement with IP67 sealing
- BAT2-PACK5 - Lithium battery
- PY2-F-150 - Rectilinear displacement transducer with ball tip
- PZ12-A-300 - Rectilinear displacement transducer with cylindrical case