4 channels Wireless Smart Datalogger - Temperature (environment or surface: selectable by jumper) or potentiometric sensor input and 3 potentiometric sensor (selectable stroke) inputs - To be used with or equivalent accessories -Type “C” internal lithium battery for a battery life up to 10 years with samples every 60 minutes - IP65 sealing.
€ 556,60
VAT and shipping excluded
Contact us
- Technical data
- Downloads
- Related products
- Case Studies
Power supply | 8.5A/h - 3.6V type “C” lithium internal battery |
Battery life (*) | Up to 10 years (samples every 60 minutes and radio signal quality at least sufficient) |
Measures acquired ( 4 input channels |
|
Sampling interval (*) | Selectable from one minute to 24 hours ( 10 minutes default) |
Datalogger capacity | 64,000 samples (for each channel) |
Working temperature |
|
Radio frequency | ISM 868MHz |
Radio coverage | Up to 6Km in line of sight(can be extended using WR12 battery powered routers) |
Sealing | IP65 |
Dimensions | 90 x 160 x 50mm |
Weight | 450g |
Case material | ABS |
Mounting | 4 points |
Connections | Wireless/USB |
Cable external diameter | 4mm minimum - 8mm maximum |
Copper wire section | 0.05 ÷ 2.5mm² / ÷ 14 AWG |
Temperature - Transducer type | NTC10KΩ |
Temperature - Measure range | -30°C ÷ +60°C |
Temperature - Measure accuracy |
|
Temperature - Measure resolution | 0.01°C |
Proportional measure - Transducer type | Potentiometer |
Proportional measure - Measure range | 0 ÷ 100% |
Proportional measure - Measure resolution | 0.01% |
Linear deformation - Transducer type | Potentiometer |
Linear deformation - Measure range | Configurable using WineCapManager - From 1mm up to 1,000mm |
Linear deformation - Measure accuracy | 0.1% analog input - Refer to potentiometer’s technical sheet |
Linear deformation - Measure resolution | 12bit |
* battery life may be influenced by fieldwork conditions, sampling interval and system configuration.
** radio coverage reachable using up to 32 WR12 routers (maximum 16 for each path) between the device and the basestation.
- PZ12-A-050 - Rectilinear displacement transducer
- GSF - Linear wire position transducer
- PY2-C-010 - Rectilinear displacement transducer with ball tip
- PY2-C-025 - Rectilinear displacement transducer with ball tip
- PY2-C-050 - Rectilinear displacement transducer with ball tip
- PY2-F-025 - Rectilinear displacement transducer with ball tip
- PY2-F-050 - Rectilinear displacement transducer with ball tip
- PY2-F-050IP65 - Rectilinear displacement transducer with ball tip
- PY2-F-100 - Rectilinear displacement transducer with ball tip
- PZ12-A-010 - Rectilinear displacement transducer with cylindrical case