WSD10TCOPM - Indoor temperature - CO₂ concentration - PM2.5 particulate - PM10 particulate

4-channel Wireless Smart Datalogger - Indoor temperature, CO2 concentration, PM2.5 particulate and PM10 particulate - Dual type "D" lithium internal battery for a battery life up to 4 years with samples every 90 minutes.

€ 1.149,50 TVA et frais de port exclus
Nous contacter
  • Données techniques
  • Téléchargements
  • Produits connexes
  • Cas d'étude
Power supply · Double 19Ah - 3,6V type “D” lithium internal battery
· Possibility of external power supply via USB-C input (5Vdc 1A)
Battery life (*)(with radio signal quality at least sufficient) · Up to 4 years – Sampling interval: 85 minutes
· Up to 3 years – Sampling interval: 60 minutes
· Up to 1.5 years – Sampling interval: 30 minutes
· Up to 9 months – Sampling interval: 15 minutes
Measures acquired
( 4 input channels)
· Indoor temperature
· CO₂ concentration
· PM2.5 particulate
· PM10 particulate
Sampling interval (*) Selectable from one minute to 24 hours (90 minutes default)
Datalogger capacity 64,000 samples (for each channel)
Working temperature · Operative: -10°C ÷ +60°C
· Warehousing: -40°C ÷ +70°C
Radio frequency ISM 868MHz
Radio coverage Up to 6Km in line of sight(can be extended using WR12 battery powered repeaters)
Sealing IP30
Dimensions 155x120x50mm
Weight 500g
Case material ABS
Mounting Fix on 3 points
Connections Wireless, USB
Indoor temperature - Transducer type NTC10KΩ
Indoor temperature - Measure range -10°C ÷ +60°C
Indoor temperature - Measure accuracy ±0.2°C in whole range
Indoor temperature - Measure resolution 0.01°C
CO2 - Measure fundamental NDIR principle
CO2 - Measure range 5,000ppm
CO2 - Measure accuracy < ±50ppm +3% of measure acquired
CO2 - Measure resolution 1ppm
CO2 - Compensations Compensation of temperature and atmospheric pressure
CO2 - Calibrations No calibration needed. Periods of fresh air presence are NOT required for auto-zeroing.
PM2.5 and PM10 particulate - Measure fundamental Laser-based scattering
PM2.5 and PM10 particulate - Measure range 1 to 1,000μg/m3
PM2.5 and PM10 particulate - Measure accuracy · ±10μg/m3@0 to 100μg/m3
· ±10%@100 to 1,000μg/m3
PM2.5 and PM10 particulate - Measure resolution 1μg/m3
PM2.5 and PM10 particulate - Certifications MCERTS

* battery life may be influenced by fieldwork conditions, sampling interval and system configuration.