2 channels Wireless Smart Datalogger - Outdoor temperature and horizontal 1°-15° dual range automatic autoscale MEMS uniaxial clinometer - Type "C" lithium internal battery for a battery life up to 5 years with samples every 60 minutes - IP67 sealing.
€ 895,40
TVA et frais de port exclus
Nous contacter
Power supply | 8.5A/h - 3.6V type “C” lithium internal battery |
Battery life (*) | Up to 5 years (samples every 60 minutes and radio signal quality at least sufficient) |
Measures acquired (2 channels) | · Rotation around the horizontal axis, parallel to the support face (WSD15TIDR) · Rotation around the orthogonal axis to the support face (WSD15TIDRA) · Temperature |
Sampling interval (*) | Selectable from one minute to 24 hours (x minutes default) |
Datalogger capacity | 128,000 samples |
Working temperature | · Operative: -30°C ÷ +60°C · Warehousing: -40°C ÷ +70°C |
Radio frequency | ISM 868MHz |
Radio coverage (**) | From 800m up to 12.8Km on sight |
Sealing | IP67 |
Dimensions | 100 x 100 x 80mm |
Weight | 1,6000g |
Case material | Aluminium |
Mounting | Wall mounting with ±2° gross setting |
Connections | Wireless/USB |
Inclination - Transducer type | Uniaxial - MEMS technology - 1°÷15° Dual Range Automatic Autoscale |
Inclination - Measure range | ±1°/±15° |
Inclination - Measure accuracy | ± 0.5% of sample |
Inclination - Measure resolution | 0.001° (±1° range) - 0.01° (±15° range) |
Inclination - Mechanical zero adjustment | ± 2° gross setting (micrometric with optional kit FIX-WSD15) |
Inclination - Cross-axis sensitivity | 4% maximum |
Inclination - Temperature variation sensibility | ±0.013%/°C temperature balance using 3° polynomial |
Inclination - Shock resistance | 20,000g |
Inclination - Measure axis | Abscissa |
Inclination - Linearity | ±0.057° in measuring range |
Inclination - Over time stability | Excellent |
Temperature - Transducer type | NTC10KΩ |
Temperature - Measure range | -30°C ÷ +60°C |
Temperature - Measure accuracy | · ± 0.5°C Range -30°C ÷ 0°C · ± 0.2°C Range 0°C ÷ +60°C |
Temperature - Measure resolution | 0.01°C |
* battery life and sampling interval may be influenced by fieldwork conditions and system configuration. ** radio coverage reachable using up to 32 WR12 routers (maximum 16 for each path) between the datalogger and the basestation.