EN
EN IT FR

Case studies

Monitoring Towers and Masts

Châtillon

Châtillon

Background

The requirement was to monitor a mast (radio base station) positioned on a slope in a valley in the province of Aosta, because of suspected subsidence of the foundations on the valley side. Aside from widespread oxidation, the structure had actually lost verticality equivalent to 1/186 of the total height of the tower.

The solution

The WineCap™ solution has two components - dual-axis inclinometers with MEMS technology, offering IP67 grade protection, and the MWDG-GSM data collection control unit placed inside the PPS box. The kit is equipped with a 10 W solar panel, lead/calcium battery and 6 A charge regulator, and can therefore operate without a mains power supply.

The result

The verticality pattern over time is conveniently monitored remotely, by viewing the data through the Service Centre. Furthermore, thanks to the two-way nature of the WineCap™ protocol, sampling frequency can be changed at any time.



Attachments


Case Studies
Service Stations
The distribution of domestic water in the network of service stations…
Champorcher Valley
In the field of advanced environmental monitoring, the collection of …
District 8 (Circoscrizione 8), Turin
With the EfficienTO project, the City of Turin and the Iren Group have …
Valsusa
Guaranteeing service continuity for installations in remote areas, where...
Royal Palace of Caserta
The Royal Palace of Caserta has been a UNESCO heritage site since 1997...
Paris 2024 Olympic Games
In the prestigious setting of the Défense Arena, one of the main venues…
San Quirico District, Genova
In the San Quirico district of Genoa, a hydraulic upgrade project was recently …
Lake Spina, Pralormo (Turin)
Lake Spina, located in Pralormo (Turin), is an artificial reservoir of…
Lyon-Turin railway tunnel
TELT - Tunnel Euralpin Lyon Turin is the dual-national developer...
Asti – Nizza Monferrato Railway Line
Monferrato Piemontese is an area of Italy that features uplands and…
Foqus Fondazione Quartieri Spagnoli, Naples
In the setting of the Spanish quarters of Naples, the new EDUQA educational…
Grand Paris Express
The main aim of the Grand Paris Express project is to reinforce the Paris...
Alla Scala Opera House
Milan’s La Scala Opera House is one of the most prestigious theatres...
Careggi Hospital in Florence
Cryogenic liquids, typically liquid nitrogen, are used for sensitive...
Foundation slab
During the cement hydration process, the heat generated by …
Villa Italia – Lake Como
The work was to renovate and extend a historic building in an extremely…
Bilbao, Spain
As part of the railway network enhancement project in the Basque Country…
RFI – Exilles tunnel
Tunnels are an integral part of railway infrastructure...
Ontario – Canada
he construction of a Verona System by the company Petrucco required…
Energy loss
CAPETTI Elettronica has always been mindful of climate change...
EDEN project
EDEN – Energy Data ENgagement – is a project that transpired from the idea...
Monitoring Bearings
A fundamental aspect in the maintenance of large works is checking…
Ipo Dam, Norzagaray - Philippines
Ipo Dam is a gravity dam with a concrete water reservoir situated at…
Historic Centre of Turin
Calculating heat consumption is crucial for managing corporate and…
Molinette Hospital in Turin
With almost 3000 hospital, school and university premises benefiting from its wireless...
Egyptian Museum in Turin
The Egyptian Museum in Turin is the oldest museum in the world...
Porto Marghera
As part of Venice’s urban regeneration RE.MO.VE project...
Sant’Agata de’ Goti
At the beginning of 2019, the Sant’Agata de’ Goti (BN) District Council ...
Ricci Oddi Art Gallery
In April 2022 the exhibition entitled Klimt - The Man, the Artist, his World...
Temple of Segesta
This spectacular Doric temple was built in the 5th century BC ...
Val Senales
There were many objectives - measure existing compression on the bridge beams...
Dubai - Mirdif Hospital
The WineCap™ data loggers for measuring temperature and humidity…
Metro 5 - Milan
Milan's M5 subway line winds along approximately 25 km of tunnels…
Châtillon
The requirement was to monitor a mast (radio base station) positioned on a slope...